SepticFixes

Septic tank size by state

Every state's minimum for 1–6 bedrooms, how it treats a garbage disposal and compartments, and who issues the permit — each figure traced to the state's own regulation text.

Updated

The short answer

Most states require at least 1,000 gal for a 3-bedroom home (39 of the 48 with a state figure). Minimums run from 900 gal (Florida, Mississippi, Pennsylvania, Tennessee and Virginia) to 1,500 gal (Massachusetts and Ohio). By state count: 5 at 900, 39 at 1,000, 2 at 1,250 and 2 at 1,500. 8 states size from daily flow or floor area rather than a bedroom table; Michigan leaves sizing to local health departments, and Wisconsin has no statewide tank table.

Loading the map…

Colour shows the minimum for a 3-bedroom home. Tap a legend entry to show only those states; small eastern states also have a labelled box on the right.

Pick a state on the map or from the list for its 1–6 bedroom minimums, disposal and compartment rules, who issues the permit, and the rule text behind each figure.

What the 50 states show

1,000 gal

for 3 bedrooms in 39 states

The same as the model code (IPSDC Table 802.7.1). 4 states require more and 5 allow less.

1,500 gal

the strictest 3-bedroom minimum

Massachusetts and Ohio, then Iowa and New Hampshire at 1,250 gal.

900 gal

the lowest 3-bedroom minimum

Mississippi, Pennsylvania, Tennessee and Virginia, and Florida for a house within its floor-area band.

8

states size from flow or floor area

By daily design flow: Delaware, Louisiana, Massachusetts, Nebraska, Pennsylvania and Vermont. By bedrooms and floor area: Florida and Texas. Arizona adds a fixture count.

14

states add capacity for a garbage disposal

5 add 50%, 4 add 250 gal, 2 use another percentage and 3 publish their own column. 5 tables already allow for one.

18

states require two compartments

Or two tanks in series, for every home. 11 more require them only in some cases.

26

states where your county may require more

The rule text lets local bodies set stricter rules or run their own programs. Wisconsin forbids local rules that differ.

100 of 286

figures are calculated, not printed

From the rule’s own formula or per-bedroom step. Each one is labelled and shows its arithmetic.

Counts cover single-family homes. The 3-bedroom counts include Arizona, Florida and Texas, whose figure depends on the house (the table shows the conditions), and California and Kansas, whose figure is a state default that county programs replace.

All 50 states: minimum tank size by bedrooms

Gallons of liquid capacity. Sort by any bedroom column; select a state for its full card and the rule text. Italic figures are calculated from the rule’s formula or per-bedroom step; upright ones are printed in the rule. Where a range is shown, the rule gives two figures — Texas without and with water-saving devices, Arizona for up to and over 7 plumbing fixture units per bedroom.

Minimum septic tank size in gallons by state and bedrooms, with the sizing basis, disposal rule, compartment rule and source. Column headers sort the table.
Sized byDisposalCompartmentsSource
1,0001,0001,0001,0001,5001,750 (calculated from the rule’s formula)BedroomsNot addressedNo statewide requirementAla. Admin. Code r. 420-3-1-.17
1,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)BedroomsNot addressedNot stated in the rule18 AAC 72.530
Depends on the house1,0001,0001,000–1,2501,250–1,5001,500–2,0002,000–2,500Bedrooms and fixture countNo capacity adjustmentTwo requiredAriz. Admin. Code R18-9-A314
1,0001,0001,0001,2501,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)BedroomsNo increase (grinders not recommended)Not required for a single tankArkansas State Board of Health
State default; county rules govern7507501,0001,2001,5001,500BedroomsAlready included in the tableTwo requiredState Water Board OWTS Policy
1,000 (calculated from the rule’s formula)1,0001,0001,2501,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)BedroomsNo kitchen-disposal adjustmentTwo requiredRegulation No. 43
1,0001,0001,0001,125 (calculated from the rule’s formula)1,250 (calculated from the rule’s formula)1,375 (calculated from the rule’s formula)Bedrooms+250 galTwo requiredConn. Public Health Code
1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)Design flowNot addressedTwo required7 Del. Admin. Code 7101
Depends on the house900 (calculated from the rule’s formula)900 (calculated from the rule’s formula)900 (calculated from the rule’s formula)1,050 (calculated from the rule’s formula)1,200 (calculated from the rule’s formula)1,350 (calculated from the rule’s formula)Bedrooms and floor areaNot addressedTwo requiredRule 62-6.008
1,0001,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)Bedrooms+50%Two requiredGa. Comp. R. & Regs. r. 511-3-1-.05
1,0001,0001,0001,0001,2505-bedroom capBedroomsNot addressedNot stated in the ruleHawaii Administrative Rules Title 11
1,0001,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)BedroomsNot addressedOptionalIDAPA 58.01.03 - Individual/Subsurface Sewage Disposal Rules and Rules for Cleaning of Septic Tanks
7507501,0001,2501,5001,750BedroomsOwn table (e.g. 3 BR 1,500)Only above 1,350 gpd77 Ill. Adm. Code 905
7507501,0001,2501,5001,800 (calculated from the rule’s formula)BedroomsNot addressedOnly with a grinder pump410 IAC 6-8.3
1,2501,2501,2501,5001,7502,000BedroomsNot addressedTwo required567 Iowa Administrative Code Chapter 69
State default; county rules govern1,0001,0001,0001,2001,5001,800 (calculated from the rule’s formula)Bedrooms3 x daily flow (e.g. 3 BR 1,350)Not requiredK.A.R. 28-5-7
1,0001,0001,0001,2501,5001,750 (calculated from the rule’s formula)Bedrooms+250 galOnly on Soil Group IV sites902 KAR 10:085
500750 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)Design flowNot addressedOptionalLouisiana Administrative Code Title 51
7507501,0001,0001,2501,500 (calculated from the rule’s formula)Bedrooms+30% is one listed optionNot required10-144 CMR Chapter 241
1,0001,0001,0001,2501,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)BedroomsAlready included in the tableTwo requiredCOMAR 26.04.02.05
1,500 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)Design flowTwo-compartment tank; no extra volumeWith a grinder or 1,000+ gpd310 CMR 15.223
Local rules onlyLocalLocalLocalLocalLocalLocalLocal codesSet locallySet locallyPart 22 Groundwater Quality Rules
1,0001,0001,0001,5001,5002,000Bedrooms+50% and compartmentsWith a disposal or ejector pumpMinn. R. 7080.1930
7507509001,2001,5001,800BedroomsNot addressedNot required15 Miss. Admin. Code Pt. 18
1,0001,0001,0001,2501,5001,580 (calculated from the rule’s formula)BedroomsAlready included in the tableSingle tanks over 1,500 gal19 CSR 20-3.060 Minimum Construction Standards for On-Site Sewage Disposal Systems
1,0001,0001,0001,5001,5002,000BedroomsNot addressedNot requiredCircular DEQ-4
1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)Design flowNext column of Table 3Single tanks over 3,000 galNeb. Admin. Code Title 124
1,0001,0001,0001,2001,5001,500BedroomsNot addressedTwo requiredNAC 444.8306
1,2501,2501,2501,2501,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)Bedrooms+50%OptionalN.H. Code Admin. R. Env-Wq 1010.01
1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)Bedrooms+50% and compartmentsWith a grinder or ejector pumpN.J.A.C. 7:9A-8.2
7501,0001,0001,2001,5001,500BedroomsNot addressedTwo required20.7.3 NMAC Liquid Waste Disposal and Treatment
1,0001,0001,0001,2501,5001,750Bedrooms+250 galTanks 10 ft+ long, or with a grinder10 NYCRR Part 75
1,0001,0001,0001,0001,2501,343 (calculated from the rule’s formula)BedroomsNot addressedTwo required15A NCAC 18E .0801 Septic Tank Capacity Requirements
1,0001,0001,0001,2001,5001,500BedroomsAlready included in the tableNo requirement statedN.D. Admin. Code ch. 62-03.1-03 Private Sewage Disposal Systems
1,0001,0001,5002,0002,0002,500+ (wording ambiguous)BedroomsNot addressedTwo required from 3 bedroomsOhio Adm. Code 3701-29-12 Tanks
1,0001,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)BedroomsNot addressedOptionalOkla. Admin. Code 252:641-7-4 Liquid capacity
1,0001,0001,0001,0001,5001,500BedroomsNot addressedWith an ejector pumpOAR 340-071-0220
900 (calculated from the rule’s formula)900 (calculated from the rule’s formula)900 (calculated from the rule’s formula)1,250 (calculated from the rule’s formula)1,400 (calculated from the rule’s formula)1,550 (calculated from the rule’s formula)Design flowAlready included in the flowTwo required25 Pa. Code § 73.31 Standards for septic tanks
1,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)Bedrooms+250 galTwo required250-RICR-150-10-6
1,0001,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)BedroomsNot addressedOptionalS.C. Code Regs. R.61-56 Onsite Wastewater Systems
1,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)Bedrooms+20%Single tanks over 3,000 galARSD 74:53:01:25 Minimum capacities for septic tanks
7507509001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)BedroomsNot addressedTwo required (tanks since 1991)Tenn. Comp. R. & Regs. 0400-48-01-.08 Septic Tank Capacity; 0400-48-01-.09 Design of Septic Tanks
Depends on the house750 (calculated from the rule’s formula)750 (calculated from the rule’s formula)750–1,000 (calculated from the rule’s formula)1,000–1,250 (calculated from the rule’s formula)1,250 (calculated from the rule’s formula)1,250–1,313 (calculated from the rule’s formula)Bedrooms, living area and water-saving devicesNot addressedTwo or three required30 TAC Chapter 285
1,0001,0001,0001,2501,500 (calculated from the rule’s formula)1,750 (calculated from the rule’s formula)BedroomsNot addressedOptionalUtah Admin. Code R317-4-6
1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,000 (calculated from the rule’s formula)1,260 (calculated from the rule’s formula)Design flow+50% (minimum)No requirementVermont Wastewater System and Potable Water Supply Rules
7507509001,2001,5001,800 (calculated from the rule’s formula)BedroomsNot addressedNo requirement12VAC5-610-815 Septic tank design
1,0001,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)BedroomsNot addressedTwo requiredWAC 246-272A-0232 Design requirements—Septic tank sizing
1,0001,0001,0001,0001,250 (calculated from the rule’s formula)1,500 (calculated from the rule’s formula)BedroomsNot addressedNot mandatedW. Va. Code R. § 64-47-6.4 Septic Tanks
No statewide tank table——————Design flowNot addressedNot stated in the codeWis. Admin. Code ch. SPS 383 Private Onsite Wastewater Treatment Systems
1,0001,0001,0001,0001,150 (calculated from the rule’s formula)1,300 (calculated from the rule’s formula)BedroomsNot addressedOptionalWyoming Water Quality Rules

How states size a septic tank

Every state starts from the same idea — the tank has to hold at least a day or two of the home’s wastewater so solids can settle — but writes it down in one of three ways.

A bedroom table

Most states print a table: so many gallons up to a bedroom count, then a fixed step for each bedroom beyond it. The steps differ more than the starting points. Connecticut adds 125 gallons a bedroom above three, Wyoming 150 above four, and most others 250. Some tables cover bands instead: Minnesota and Montana jump from 1,000 to 1,500 gallons at four bedrooms and to 2,000 at six.

A flow formula

Delaware, Louisiana, Massachusetts, Nebraska, Pennsylvania and Vermont set a daily design flow per bedroom and size the tank as a multiple of it, often with a floor. Massachusetts’ 1,500-gallon floor is above what its formula gives for up to six bedrooms, so every home up to six bedrooms gets 1,500. Pennsylvania’s formula gives 900 gallons for up to three bedrooms and 1,250 for four — a 350-gallon step, not a flat per-bedroom figure. For these states each figure here is calculated from the formula and shows its arithmetic.

Something besides bedrooms

Texas sizes from a flow that depends on living area and water-saving devices, so a 3-bedroom house (living area under 2,500 sq ft) needs 1,000 gal without devices and 750 gal with them. Florida uses whichever of bedrooms or building area gives the larger flow. Arizona adds a count of plumbing fixture units, and from 3 bedrooms up a house with more than 7 per bedroom needs the next size.

Work out your own house in the tank size calculator

Garbage disposals

A disposal sends food solids to the tank, and the model code adds 50% for one. The states don’t agree:

  • Add 50%: Georgia, Minnesota, New Hampshire, New Jersey and Vermont.
  • Another percentage: Maine (+30% is one listed option), South Dakota (+20%). Maine’s rule says disposals “should not be used” with disposal fields and lists more capacity as one of several measures if one is.
  • Add 250 gallons: Connecticut, Kentucky, New York and Rhode Island.
  • Their own figures: Illinois (own table (e.g. 3 br 1,500)), Kansas (3 x daily flow (e.g. 3 br 1,350)), Nebraska (next column of table 3).
  • Already allowed for in the table or flow: California, Maryland, Missouri, North Dakota and Pennsylvania.
  • No extra volume, other conditions: Arkansas (no increase (grinders not recommended)), Massachusetts (two-compartment tank; no extra volume).
  • Not addressed: the other 28 states’ rules don’t mention a disposal in sizing the tank.

Where a rule is silent, a bigger tank still gives the solids more room and stretches the time between pump-outs; it just isn’t required.

Two compartments or one

A second compartment (or a second tank in series) keeps more solids out of the drain field. 18 states require one for every home: Arizona, California, Colorado, Connecticut, Delaware, Florida, Georgia, Iowa, Maryland, Nevada, New Mexico, North Carolina, Ohio, Pennsylvania, Rhode Island, Tennessee, Texas and Washington. 11 require it only in some cases — with a garbage disposal or ejector pump, above a tank size or flow, or on poor soil. The rest allow a single-compartment tank, though several set proportions if you use two, and 4 say nothing in the rule reviewed.

State rule, county permit

The state rule is a minimum; the permit usually comes from a county or district health department, and it has the final say. In 26 states the rule text lets local bodies set stricter requirements or run their own programs — each card flags it. Three cases stand out:

  • Michigan has no statewide rule for single-family homes; each local health department’s sanitary code sets the size.
  • California and Kansas: county programs replace the state figure where they exist (California’s approved Local Agency Management Programs, Kansas’s county sanitary codes). The figures shown are the state defaults.
  • Wisconsin sets the design flow but has no minimum tank table; the tank is sized in the approved design.

Before you buy a tank or accept a quote, ask the office that issues the permit which figure it applies. If it differs from the one here, theirs governs.

Methodology and limits

Official regulation text only. Each state was researched from its administrative code, statute, or the state agency’s own rule or official guidance — no installer sites, tank sellers or summaries. The 50 records cite 145 sources and carry 421 passages of rule text, shown on each state’s card.

An independent second pass. Every value and quote was then re-checked against the live source on September 26, 2026. That pass corrected citations, compartment rules and dates, removed figures that were inferred rather than stated (such as absolute minimums read off the smallest table row, and a per-bedroom increment for Mississippi found only in unofficial copies), and flagged Ohio’s 6-bedroom wording as unresolved rather than choosing a reading. No bedroom figure changed.

Stated or calculated. 186 figures are printed in a rule; 100 are calculated from the rule’s own formula or per-bedroom step, and our build re-does each calculation and fails if it doesn’t reproduce the verified figure. Where a rule leaves rounding unstated (North Carolina, Texas at 6 bedrooms) we round up and say so.

Limits. Figures are minimum liquid capacity for a single-family home using a conventional septic tank; aerobic units, nitrogen-reducing systems and other alternatives follow their own approvals. Rules change, and local codes can add to them.

This is a research summary, not permit advice. The local health department issues the permit; confirm the minimum for your property with it before you buy a tank.

Download or cite the data

The full table — all 50 states, 1–6 bedroom figures with how each was obtained, the disposal and compartment rules, authority, regulation and every source URL — is free to reuse under CC BY 4.0: credit Septic Fixes with a link to this page.

Download the CSV (70 KB)

Cite this data

Septic Fixes (2026). Minimum septic tank size by state, verified September 26, 2026. https://www.septicfixes.com/septic-tank-size-by-state

Linking to one state? Add ?state= and its two-letter code, such as ?state=TX, to this page or to the calculator.

Frequently asked questions

What size septic tank do I need for a 3-bedroom house?
In most states at least 1,000 gal (39 of 48 with a state figure). The range runs from 900 gal (Florida, Mississippi, Pennsylvania, Tennessee and Virginia) to 1,500 gal (Massachusetts and Ohio). By state: Texas 750–1,000*; Florida 900*; North Carolina 1,000; Pennsylvania 900; Michigan: set locally; Ohio 1,500; Georgia 1,000; New York 1,000 (* depends on the house). Your county can require more.
What size septic tank do I need for a 4-bedroom house?
Most often 1,250 gal (18 of 48 states with a figure); the largest is 2,000 gal in Ohio.
Does a garbage disposal change the septic tank size?
In 14 states it does: 5 add 50%, 4 add 250 gallons, 2 use another percentage and 3 publish their own figures. In 5 the table already allows for one; the rest don’t mention disposals.
Who sets septic tank size — the state or the county?
The state sets a minimum; the county or local health department issues the permit. In 26 states local bodies can require more or run their own programs. Michigan leaves it entirely to local codes; in California and Kansas county programs replace the state default.
Which state requires the biggest septic tank?
Massachusetts and Ohio, at 1,500 gal for 3 bedrooms, then Iowa and New Hampshire at 1,250 gal.
Do septic tanks need two compartments?
Required in 18 states, required only in some cases in 11, and optional in 17.

Keep going